Abstract/Notes
INTISARI
Fathuba Bimayakfika, 2020, NIT : 52155712.T, “Analisis Terjadinya Black out
Pada Diesel Generator Di MT. Minas”, skripsi Program Studi
Teknika, Progran Diploma IV, Politeknik Ilmu Pelayaran
Semarang, Pembimbing I: Dwi Prasetyo, M.M, M.Mar.E. dan
Pembimbing II: Dr., Winarno, S.ST, M.H
Diesel generator berfungsi mengubah tenaga mekanis menjadi tenaga
listrik arus bolak-balik. Arus bolak-balik sering juga di sebut sebagai Alternator,
Generator AC (Alternating Current) atau generator sinkron. Dikatakan generator
sinkron karna jumlah putaran rotornya sama dengan jumlah putaran medan
magnet pada stator. Kecepatan sinkron ini di hasilkan dari kecepatan putaran
rotor dengan kutub-kutub magnet yang berputar dengan kecepatan yang sama
dengan medan putar pada stator. Mesin ini tidak dapat di jalankan sendiri karena
karena kutub-kutub rotor tidak dapat tiba-tiba mengikuti kecepatan medan putar
pada waktu saklar penghubung dengan jala-jala generator arus bolak-balik.
Jenis metode penelitian yang peneliti gunakan dalam penyusunan skripsi
ini adalah deskriptif kualitaf dengan menggunakan pendekatan fishbone analysis
dan SHELL untuk mempermudah dalam teknik analisis data. Peneliti juga
menggunakan metode pengumpulan data yang peneliti lakukan adalah dengan
cara observasi, dokumentasi dan wawancara untuk memperkuat dalam analisis
data dan pembahasan. Tujuan dari penelitian ini adalah untuk mengetahui faktor
penyebab terjadinya black out pada diesel generator, dampak dari faktor
penyebab terjadinya black out pada diesel generator dan upaya yang dilakukan
untuk mencegah faktor penyebab terjadinya black out pada diesel generator di
MT. Minas.
Berdasarkan hasil penelitian peneliti, dapat disimpulkan bahwa faktor
penyebab terjadinya black out pada diesel generator di MT. Minas adalah, 1)
perawatan tidak terlaksana akibat tidak berjalanya DO Purifier. Dampak yang
ditimbulkan adalah 1) ketidaknormalan DO Purifier karena tidak terlaksananya
perawatan. Upaya mencegah terjadinya black out pada diesel generator yang
harus dilakukan adalah dengan, 1) melaksanakan perawatan DO Pirifier sesuai
dengan PMS, melakukan perbaikan ataupun penggantian terhadap komponen DO
Purifier yang rusak dengan melakukan overhaul.


ABSTRACT
Fathuba Bimayakfika, 2020, NIT: 52155712.T, "Analysis of the Black Out
Occurrence of Diesel Generators in MT. Minas ", thesis of Engineering
Study Program, Diploma IV Program, Semarang Shipping Polytechnic,
Advisor I: Dwi Prasetyo, M.M, M.Mar.E. and Advisor II: Dr., Winarno,
S.ST, M.H.
Diesel generator functions to convert mechanical power into alternating
current electric power. Alternating current is often also referred to as Alternator,
AC Generator (Alternating Current) or synchronous generator. It is said to be a
synchronous generator because the number of rotations of the rotor is the same as
the number of rotations of the magnetic field on the stator. This synchronous
speed is produced from the rotational speed of the rotor with the magnetic poles
rotating at the same speed as the rotating field on the stator. This machine cannot
be operated alone because the rotor poles cannot suddenly follow the speed of the
rotating field at the time of the connecting switch with alternating current
generator grids.
The type of research method used by researchers in the preparation of this
thesis is descriptive quality using fishbone analysis and SHELL approaches to
facilitate data analysis techniques. Researchers also use data collection methods
that researchers do is by observation, documentation and interviews to strengthen
the data analysis and discussion. The purpose of this study was to determine the
factors causing black outs on diesel generators, the impact of the factors causing
black outs on diesel generators and efforts made to prevent the causes of black
outs on diesel generators in MT. Minas.
. Based on the research results of researchers, it can be concluded that the
factors causing the black out of diesel generators in MT. Minas is, 1) maintenance
is not carried out due to DO not run Purifier. The impact is 1) DO Purifier
abnormalities due to not implementing the treatment. Efforts to prevent black outs
on diesel generators that must be done are by, 1) carrying out DO Pirifier
maintenance in accordance with PMS, repairing or replacing damaged DO
Purifier components by overhauling.