INTI SARI
Anthare D.A.S.N.H, 2019, NIT : 52155733. T, “Analisis Penurunan Produksi
Air Tawar Pada fresh water generator di MV. Meratus
Project 1”, skripsi Progam Studi Teknika, Program
Diploma IV, Politeknik Ilmu Pelayaran Semarang,
Pembimbing 1 : Abdi Seno, M.Si., M.Mar.E. dan
Pembimbing II : Yustina Sapan S.ST, M.M.
Fresh water generator adalah suatu mesin yang berfungsi untuk mengubah
air laut menjadi air tawar dengan prinsip memanfatkan kevakuman untuk proses
evaporasi dan kondensasi. Pesawat ini memiliki peranan sangat penting dalam
kelancaran pengoperasian kapal, dimana dalam pengoperasian kapal tidak terlepas
dari kebutuhan akan air tawar. Penelitian ini bertujuan untuk dapat mengetahui
penyebab, dampak, serta upaya yang terjadi pada fresh water generator sehingga
dapat meningkatkan hasil produksi air tawar pada fresh water generator di kapal.
Metode penelitian yang penulis gunakan dalam penyusunan skripsi ini
adalah metode penelitian deskriptif kualitatif dengan menggunakan pendekatan
fishbone sebagai teknik analisa data. Metode fishbone berbentuk menyerupai
tulang ikan yang bagiannya menyerupai kepala dan tulang ikan. Diagram fishbone
juga disebut diagram cause and effect (sebab dan akibat) karena diagram tersebut
menunjukan hubungan antara sebab dan akibat dari faktor penyebab
permasalahan, dampak yang ditimbulkan serta upaya yang dilakukan untuk
mencegah turunya produksi air tawar pada fresh water generator di MV.Meratus
Project 1.
Hasil penelitian yang dilakukan, dapat disampaikan bahwa turunya produksi
air tawar pada mesin fresh water generator di MV.Meratus Project 1 disebabkan
oleh rusaknya packing pada pelat evaporator, kurangnya tekanan ejector suply
pump, kelalaian seorang engineer, dan kesalahan prosedur pengoprasian,
banyaknya kerak pada pelat evaporator. Dampak yang disebabkan dari faktor
adalah kurangnya kevakuman, proses kondensasi tidak sempurna, timbulnya
kerusakan mesin yang mengganggu kinerja mesin, timbulnya masalah baru pada,
proses evaporasi tidak bisa sempurna. Untuk mencegah faktor faktor tersebut
dapat dilakukan upaya dengan mengganti packing yang sudah rusak,
membersihkan filter pompa, membuat tabel scheadule maintenance yang ditanda
tangani oleh KKM, mempelajari panduan dari manual book, membersihkan kerek
kerak pada pelat evaporator.


ABSTRACTION
Anthares D.A.S.N.H, 2019, NIT: 52155733. T, "Analysis of Freshwater Production
Reduction in Fresh Water Generators in MV. Meratus
Project 1", thesis of Engineering Study Program, Diploma IV
Program, Semarang Shipping Polytechnic, Advisor 1: Abdi
Seno, M.Sc., M.Mar.E. and Advisor II: Yustina Sapan S.ST,
M.M.
Fresh water generator is a machine that functions to convert sea water into fresh
water with the principle of utilizing a vacuum for the evaporation and condensation
process. This aircraft has a very important role in the smooth operation of the ship,
where the operation of the ship is inseparable from the need for fresh water. This
study aims to determine the causes, impacts, and efforts that occur in fresh water
generators so as to increase the yield of fresh water production in fresh water
generators on ships.
The research method that the author uses in the preparation of this description is
a qualitative descriptive research method using the fishbone approach as a data
analysis technique. The fishbone method is shaped like a fish bone whose parts
resemble the head and bones of a fish. Fishbone diagrams are also called cause and
effect diagrams because they show the relationship between the causes and effects of
the causes of the problem, the impacts caused and the efforts made to prevent fresh
water production from falling in fresh water generators in MV.Meratus Project 1.
The results of the research carried out, can be conveyed that the fall in fresh
water production in fresh water generator machines in MV. Status Project 1 is caused
by damage to the packing on the evaporator plate, lack of pressure ejector supply
pump, negligence of an engineer, and errors in the operating procedure, the amount of
crust on the plate evaporator. The impact caused by factors is the lack of vacuum, the
process of imperfect condensation, the emergence of engine damage that interferes
with engine performance, the emergence of new problems in, the evaporation process
cannot be perfect. To prevent these factors efforts can be made by replacing damaged
packaging, cleaning the pump filter, making a maintenance scheadule table signed by
KKM, studying the guidelines from the manual book, cleaning the scale of the
evaporator plate.