ABSTRAKSI
Wasis Novebar Armanah, NIT. 52155729.T, 2018 “Identifikasi high water level
alarm pada Sewage Treatment Plant yang terus menerus berbunyi di KM.
Pusri Indonesia 1”, Program Diploma IV, Teknika, Politeknik Ilmu
Pelayaran Semarang, Pembimbing I: H. Amad Narto, M.Pd, M.Mar.E dan
Pembimbing II: Andy Wahyu Hermanto, MT
Sewage Treatment Plant merupakan salah satu sistem permesinan bantu yang
digunakan untuk memproses limbah atau kotoran manusia di atas kapal agar limbah
tersebut dapat dibuang ke laut dan tidak menimbulkan pencemaran lingkungan laut.
Latar belakang penulisan skripsi ini adalah terjadinya high water level alarm yang
terus menerus pada Sewage Treatment Plant, sehingga air limbah pada Sewage
Treatment Plant keluar melalui over flow. Rumusan masalah pada penelitian ini
adalah bagaimana prinsip kerja high water level alarm pada Sewage Treatment
Plant?, apakah akibat yang timbul dari high water level alarm yang tidak bekerja
dengan baik? dan apakah upaya apa yang dilakukan untuk mengatasi masalah
sewage treatment plant agar bekerja dengan normal?
Penelitian skripsi ini menggunakan metode fishbone analysis dan fault tree
analysis (FTA) dalam menyelesaikan masalah. Menggunakan metode fishbone
didapatkan empat faktor penyebab high water level yaitu faktor mesin, metode,
manusia dan material. Menggunakan FTA penulis mengidentifakasi faktor tersebut
menjadi dua faktor yaitu mesin dan material. Top event dari masalah high water
level alarm pada sewage treatment plant yaitu penyumbatan probe level dan
penyumbatan impeller discharge pump.
Resiko yang ditimbulkan dari adanya penyumbatan pada probe level dan
impeller discharge pump pada Sewage Treatment Plant yaitu terjadinya high water
level alarm yang terus menerus dan menyebabkan Sewage Treatment Plant bekerja
tidak optimal, yang ditandai dengan keluarnya air limbah melalui over flow yang
menyebabkan terjadinya luapan air pada dirty water tank. Metode perawatan
Sewage Treatment Plant harus dilakukan dengan baik dan teratur sesuai dengan
plan maintenance system yang telah diprogramkan agar kerusakan pada Sewage
Treatment Plant dapat dihindari.










ABSTRACT
Wasis Novebar Armanah, NIT. 52155729.T, 2019 "Identification the
continuously alarm high water level of Sewage Treatment Plant at MV.
Pusri Indonesia 1”, Diploma IV Programe, Technical, Politeknik Ilmu
Pelayaran Semarang, Supervisor I: H. Amad Narto, M.Pd, M.Mar.E and
Supervisor II: Andy Wahyu Hermanto, MT
Sewage Treatment Plant is one of the auxiliary machinery systems used to
process sewage or human waste on board so that waste can be discharged into the
sea and does not cause pollution of the marine environment. The background of this
thesis is the continuously alarm high water level of Sewage Treatment Plant, so
that the waste water from Sewage Treatment Plant through over flow. Formulation
of the problem in this study is how the water sensor of Sewage Treatment Plant
work?, What the effect that arise from high water level alarm which is not working
properly? and whether efforts to resolve the problem so Sewage Treatment Plant is
working normally?
The method used by the writer is fishbone analysis and fault tree analysis.
Factor that the writer find from fishbone analysis is material, method, machine, and
man. Use fault tree analysis the writer identification two factor, it is machine and
material. The top event from the problem which make alarm of high water level in
Sewage Treatment Plant is the probe level gagged by the trash and the impeller of
discharge pump gagged by the trash.
The conclusion of this study is the risk arising from the clogging of probe
level and discharge pump’s impeller at Sewage Treatment Plant is continuously
alarm high water level and causes Sewage Treatment Plant works not optimal, it is
characterized by the discharge of waste water through over flow that makes
flotation of waste water in dirty water tank. Maintenance of Sewage Treatment
Plant should be done properly and regularly in accordance with the plan
maintenance system that has been programmed so that damage to the Sewage
Treatment Plant can be avoided.