ABSTRAKSI
Prisma Dwi Avrianto, 52155750. T, 2019, “Identifikasi turunnya tekanan pada
Emergency Fire Pump di SV. NMS Bravery”, skripsi Program Studi
Teknika, Program Diploma IV, Politeknik Ilmu Pelayaran Semarang,
Pembimbing I: H. Amad Narto, M.pd, M.Mar.E, Pembimbing II: Ir,
Fitri Kensiwi,M.Pd.
Kapal dapat mengalami kecelakaan misalnya terjadi kebakaran oleh karena
itu kita harus memperhatikan tentang dampak dari bahaya kebakaran khususnya
dilaut.Mengingat hal tersebut maka kemampuan emergency fire pump sangat
penting guna memadamkan kebakaran yang terjadi sewaktu–waktu dan demi
tercapainya rasa aman dan nyaman untuk semua kru. Selain itu kemampuan
emergency fire pump ini juga sangat penting guna mengurangi kerugian material
maupun nyawa kru.
Metode yang digunakan dalam skripsi ini adalah metode Deskriptif Kualitatif
dengan teknik analisa fishbone dan fault tree analysis sebagai metode untuk
menentukan penyebab dan upaya untuk menanggulanginya.Adapun rumusan
masalah dari penelitian ini adalah faktor-faktor apa saja yang mempengaruhi
turunnya tekanan pada emergency fire pump, dampak turunnya tekanan pada
pompa, dan upaya yang dilakukan untuk mengatasi turunnya tekanan pada pompa.
Faktor utama yang menyebabkan turunnya tekanan pada emergency fire
pump yaitu ausnya impeller pada pompa dan kebocoran pada pipa (flange) yang
diakibatkan terjadinya korosi serta rusaknya packing. Dampak turunnya tekanan
pada emergency fire pump yaitu adanya penurunan kapasitas air pada pompa dan
pompa tidak dapat menghasilkan tekanan yang maksimal.Upaya yang dilakukan
agar tekanan emergency fire pump menjadi optimal yaitu dengan mengeluarkan
udara yang ada pada rumah pompa dan membersihkan saringan serta
menggunakan saringan yang bersih dan baik.










ABSTRACT
Prisma Dwi Avrianto, 52155750. T, 2019, "Identification of pressure drops on
the Emergency Fire Pump in SV. NMS Bravery ", Thesis of
Engineering Study Program, Diploma IV Program, Semarang
Shipping Science Polytechnic, Advisor I: H. Amad Narto, M.pd,
M.Mar.E, Advisor II: Ir, Fitri Kensiwi, M.Pd.
Ships can experience accidents such as a fire, therefore we must pay attention
to the effects of fire hazards, especially at sea. Given this, the ability of the
emergency fire pump is very important to extinguish fires that occur at any time
and in order to achieve a sense of security and comfort for all crews. Besides that
the ability of the emergency fire pump is also very important to reduce material
losses and the lives of the crew.
The method used in this thesis is Qualitative Descriptive method with
fishbone analysis and fault tree analysis techniques as a method to determine the
causes and efforts to overcome them. As for the problem formulation of this study
are the factors that influence the pressure drop on the emergency fire pump, the
impact pressure drops on the pump, and efforts made to overcome the pressure
drop on the pump.
The main factor that causes a decrease in pressure on the emergency fire
pump is the wear of the impeller on the pump and the leakage of the pipe (flange)
caused by corrosion and damage to the packing. The impact of the decrease in
pressure on an emergency fire pump, namely a decrease in water capacity at the
pump and pump can not produce maximum pressure. Efforts are made so that the
emergency fire pump pressure is optimal by removing the air in the pump house
and cleaning the filter and using a clean filter and good.