Integrated Transport Resource Catalog

Pepustakaan Pusat Kementerian Perhubungan Republik Indonesia

Title
ANALISIS PENGARUH KUALITAS MINYAK LUMAS dan AIR PENDINGIN TERHADAP KINERJA COOLER ( METODE SPSS ) di KAPAL AHTS. LOGINDO DESTINY dan STRATEGI OPTIMASI KINERJA COOLER ( METODE SWOT dan AHP) ( STUDI PERSEPSI TERHADAP TARUNA TEKNIKA VII PIP Semarang )
Collection Location
Repository PIP Semarang
Edition
Call Number
ISBN/ISSN
Author(s)
HABIB, MUHAMMAD Y
Subject(s)
Teknika
Classification
Series Title
GMD
Electronic Resource
Language
Publisher
Publishing Year
2024
Publishing Place
Collation
Abstract/Notes
ABSTRAKSI
Habib Muhammad Yusuf, 2019, NIT: 5114580 T, “Analisis pengaruh minyak lumas dan air
pendingin terhadap kinerja Cooler ( metode SPSS) dan strategi optimasi kinerja Cooler (
metode SWOT dan AHP) di kapal AHTS Logindo Destiny ( studi terhadap persepsi
taruna TVII PIP Semarang)”, skripsi Program Studi Teknika, Program Diploma IV,
Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Dr. A. Agus Tjahjono, MM.,
M.Mar.E., Pembimbing II: Sri Suyanti, S.S.
Cooler merupakan alat penukar kalor yang berfungsi mendinginkan oli yang
menggunakan fluida pendingin yaitu air. Pada cooler terdapat dua siklus yang saling
berkaitan, yaitu siklus fluida dingin (air) dan siklus fluida panas (oli), yang keduanya
dalam arah berlawanan (Counter flow). Cooler merupakan perangkat penting untuk
Diesel Generator dikarenakan mempegaruhi sistem pelumasan dan sistem
pendinginan Diesel Generator.
Metode penelitian ini penulis menggunakan metode SPSS sebagai teknik
analisa data untuk menganalisa korelasi antara variabel bebas dan variabel terikat,
metode SWOT untuk menganalisa berbagai faktor yang dapat dijadikan pilihan
dalam mengoptimasi kinerja dari cooler secara sistematis terhadap kekuatan
(strenghts), kelemahan (weaknesses), peluang (opportunities), serta ancaman
(threats) untuk merumuskan strategi yang akan diambil, metode AHP untuk
menganalisa hasil dari metode SWOT sehingga didapatkan satu pilihan terbaik
berdasarkan output tersebut.
Berdasarkan hasil penelitian yang telah dilakukan penulis di kapal dan di
kampus PIP Semarang dapat disimpulkan bahwa variabel bebas berkorelasi
terhadap variabel terikat sehingga dapat dijadikan parameter untuk menentukan
kualitas varabel terikat. Kemudian strategi optimasi kinerja cooler menggunakan
strategi analisis SWOT yaitu strategi defensif yang berada di kuadran IV, terdapat
dua faktor upaya untuk mengoptimasi kinerja cooler yaitu melakukan pengetesan
air pendingin oleh Engieneer yang berkompeten dan melakukan permintaan suku
cadang sesuai manual book. Pengolahan output SWOT menggunakan metode
AHP menghasilkan satu pilihan terkuat yaitu melakukan pengetesan air pendingin
oleh Engineer yang berkompeten.






ABSTRACT
Habib Muhammad Yusuf, 2019, NIT: 5114580 T, “Analysis of the Effect of Lubricating Oil and
Cooling Water on Cooler Performance (SPSS Method) and Cooler Performance
Optimization Strategy (SWOT and AHP Methods) on the AHTS Logindo Destiny (study by
the perception of cadets of TVII PIP Semarang) ", Thesis of Technical Study Program,
Diploma IV Program, Politeknik Ilmu Pelayaran Semarang, Advisor I: Dr. A. Agus
Tjahjono, MM., M.Mar.E., Advisor II: Sri Suyanti, S.S.
Cooler is a heat exchanger machine that operates to cool oil down using cooling
fluid, specifically water. In the cooler there are two interrelated cycles, namely the cold
fluid (water) cycle and the hot fluid (oil) cycle, both of which are in counter flow. Cooler
is an essential machine for diesel generator for the reason that it affects the
lubrication system and the diesel generator cooling system.
The research method used is the SPSS method as a data analysis technique
to analyze the correlation between the independent variables and the dependent
variables, the SWOT method to analyze various factors that can be used as a
alternatives in optimizing the performance of the cooler systematically against
strenghts, weaknesses, opportunities, and threats to formulate a strategy to be
taken, the AHP method to analyze the results of the SWOT method so that the
best option is obtained based on the output.
Based on the results of research conducted by the author on board and in
PIP Semarang, it can be concluded that the independent variable correlates to the
dependent variable so that it can be used as a parameter to determine the quality of
dependent variables. Therefore the performance optimization strategy cooler uses
the SWOT analysis strategy, which is defensive strategy in quadrant IV, there are
two methods to optimize cooler performance, which are testing cooling water by
competent Engineers and requesting spare parts according to the manual book.
Processing SWOT output using the AHP method produces one of the best
choices, namely testing the cooling water by a competent Engineer.