Integrated Transport Resource Catalog

Pepustakaan Pusat Kementerian Perhubungan Republik Indonesia

Title
IDENTIFIKASI KETIDAKSTABILAN SUHU STEAM HEATER PADA CHAMBER I DOUBLE EFFECT SUBMERGED TUBE TYPE FRESH WATER GENERATOR DI SS. TANGGUH TOWUTI
Collection Location
Repository PIP Semarang
Edition
Call Number
ISBN/ISSN
Author(s)
NYATA, KEN A
Subject(s)
Teknika
Classification
Series Title
GMD
Electronic Resource
Language
Publisher
Publishing Year
2024
Publishing Place
Collation
Abstract/Notes
ABSTRAK
Nyata Ken Adityatama Nugraha, 2019, NIT: 51145481 T, “Identifikasi
Ketidakstabilan Suhu Steam Heater pada Chamber I Double Effect
Submerged Tube Type Fresh Water Generator di SS. Tangguh
Towuti”, Skripsi Teknika, Program Diploma Program IV, Politeknik
Ilmu Pelayaran Semarang, Pembimbing I: Amad Narto, M.Mar.E,
M.Pd. Pembimbing II: Henny Wahyu W., M.Pd
Fresh water generator adalah pesawat pembuat air tawar dengan cara
menguapkan air laut di dalam penguap (evaporator) dan uap air laut tersebut
didinginkan dengan cara kondensasi di dalam pesawat destilasi/kondenser
(pengembun), sehingga menghasilkan air kondensasi yang disebut kondensat.
Ketidakstabilan suhu steam heater pada chamber I double effect submerged tube
type fresh water generator di SS. Tangguh Towuti mengakibatkan tidak lancarnya
pengoperasian fresh water generator. Tujuan dari penelitian ini adalah untuk
mengetahui faktor apa saja yang menyebabkan ketidakstabilan suhu steam heater,
dampak apa saja yang disebabkan oleh tidak stabilnya suhu steam heater dan upaya
yang dilakukan untuk mengatasi penyebab tidak stabilnya suhu steam heater di SS.
Tangguh Towuti..
Penelitian ini menggunakan metode deskriptif kualitatif dengan
menggunakan teknik analisis data Software, Hardware, Environment dan Liveware
(SHEL) dan Urgency, Seriousness dan Growth (USG). Pengumpulan data dilakukan
dengan cara wawancara, dokumentasi, observasi dengan mengamati pada saat
perawatan dan perbaikan di SS. Tangguh Towuti.
Hasil penelitian ini menunjukkan bahwa ketidakstabilan suhu steam heater
diakibatkan tertutupnya steam heater tube oleh kerak/scale yang sudah cukup tebal
yang berdampak pada terganggunya proses perpindahan panas pada chamber I,
penurunan jumlah produksi air tawar dan kerusakan pada komponen brine pump.
Upaya yang dilakukan untuk mengatasi penyebab tidak stabilnya temperatur steam
heater adalah dengan menggunakan scale inhibitor sebagai penghambat
pembentukan kerak/scale, pembersihan kerak/scale, pengaturan temperature
controller sesuai manual book, pengaturan jumlah feed water, peningkatan
kevakuman dan penurunan heating temperature.







ABSTRACT
Nyata Ken Adityatama Nugraha, 2019, NIT: 51145481 T, “Instability
Identification of Steam Heater’s Temperature at the First Chamber
of Double Effect Submerged Tube Type Fresh Water Generator on
SS. Tangguh Towuti”, Technical Thesis, Diploma IV Program,
Merchant Marine Polythecnic Semarang, Material Adviser (I):
Amad Narto, M.Mar.E, M.Pd. Methodology and Writing Adviser
(II): Henny Wahyu W., M.Pd
Fresh water generator is a device used to generate fresh water by evaporating
sea water in the evaporator and vapor will condensed by condensation process in
the condenser, generated water called condensate. Instability of steam heater’s
temperature at the first chamber of double effect submerged tube type fresh water
generator on SS. Tangguh Towuti results in the obstructed operation of fresh water
generator. The purpose of this research was to find out what are the factors that
caused instability of steam heater’s temperature, impacts that caused by instability
of steam heater’s temperature and what are the ways to overcome instability of
steam heater’s temperature on SS. Tangguh Towuti.
This research uses qualitative descriptive method by data analysis technique
Software, Hardware, Environment and Liveware (SHEL) and Urgency, Seriousness
and Growth (USG). Data collection is done by interview, documentation,
observation by observing while maintenance and repair performed on SS. Tangguh
Towuti.
The result of this research shows that instability of steam heater’s temperature
caused by thick scale which is blocked the surface of steam heater tube lead to bad
heat exchanging process at the first chamber, reduction of fresh water generated
and damage of brine pump’s component. The ways to overcome instability of steam
heater’s temperature are by using scale inhibitor to inhibit the scale forming,
cleaning the scale, adjustment of temperature controller referring to manual book,
adjustment of feed water flowrate, increasement of vacuum and decreasement of
heating temperature.