Arfiendho Gagah Prayoga, 2019, NIT: 51145430T, “Analisis Pengaruh
Timbulnya Scale Pada Feed Water Side Evaporator Terhadap Kerja
Flash Type Fresh Water Generator Di Kapal LNG/C SS. Tangguh Batur”,
skripsi Program Studi Teknika, Program Diploma IV, Politeknik Ilmu
Pelayaran Semarang, Pembimbing I: Abdi Seno, M.Si, M.Mar.E,
Pembimbing II: Daryanto, SH, MM.
Flash type fresh water generator di atas kapal LNG/C digunakan untuk
memenuhi kebutuhan air tawar untuk akomodasi dan operasional permesinan yang
membutuhkan. Salah satu bagian penting dari flash type fresh water generator
adalah feed water side evaporator yang berfungsi untuk menguapkan air laut
dengan menggunakan media pemanas steam, yang tentunya tidak boleh timbul
kerak atau scale pada bagian tersebut karena akan mempengaruhi kerja dari fresh
water generator itu sendiri. Tujuan dari penelitian ini adalah untuk mengetahui
faktor yang menyebabkan timbulnya scale pada feed water side evaporator,
dampak dari faktor yang menyebabkan timbulnya scale pada feed water side
evaporator, dan upaya untuk mengatasi faktor yang menyebabkan timbulnya scale
pada feed water side evaporator.
Metode yang digunakan dalam penelitian ini adalah kualitatif. Dalam skripsi
ini penulis menggunakan teknik analisa data SHEL dan USG. SHEL digunakan
untuk menentukan kemungkinan faktor masalah berdasarkan software, hardware,
environment, lifeware, dan kemudian dianalisis menggunakan teknik analisis data
USG (urgency, seriousness, growth) untuk menentukan faktor masalah yang
menjadi prioritas utama. Teknik pengumpulan data berupa pendekatan terhadap
obyek melalui observasi, wawancara serta studi pustaka.
Berdasarkan hasil penelitian yang telah dilakukan penulis, dapat disimpulkan
bahwa timbulnya scale pada feed water side evaporator disebabkan oleh perawatan
yang dilakukan tidak sesuai maintenance plan, adanya trouble pada chemical
dosing pump, kadar garam air laut yang sangat tinggi, dan kurangnya pengetahuan
dan pengalaman engineer tentang flash type fresh water generator. Hal tersebut
berdampak pada timbulnya scale dan penurunan produksi air tawar. Untuk
mengatasi faktor-faktor tersebut dapat dilakukan dengan melakukan descaling
sesuai dengan jadwal maintenance plan, melakukan daily inspection dan perawatan
pada chemical dosing pump, melakukan penginjeksian chemical dosing sesuai buku
manual, memberikan training dan ujian serta familiarisasi kepada engineer tentang
flash type fresh water generator diatas kapal.



ABSTRACT
Arfiendho Gagah Prayoga, 2019, NIT: 51145430T, “Analysis the Effect of Scale
on Feed Water Side Evaporator to Flash Type Fresh Water Generator’s
Work on LNG/C Vessel SS. Tangguh Batur”, Minithesis of Engine
Department, Diploma IV Program, Merchant Marine Polytechnic of
Semarang, Supervisor I: Abdi Seno, M.Si, M.Mar.E and Supervisor II:
Daryanto, SH, MM.
Flash type fresh water generator on LNG/C vessel is used to fulfill fresh
water consumption on accommodation and operation of machineries. One of
important part on flash type fresh water generator is feed water side evaporator
which is used to boil sea water with heating steam. It is not good if there is a lot
of scale inside because it will affect fresh water generator’s work. The purpose of
this mini thesis are to know the factors which cause scale inside of feed water side
evaporator, the impact of the factors which cause scale inside of feed water side
evaporator and the efforts of the factors which cause scale inside of feed water side
evaporator.
The metods in this mini thesis are qualitative, then it is analyzed by SHEL
and USG. SHEL method is used to find the possibility of any factors by software,
hardware, environment, lifeware, and then analyzed by USG method (urgency,
seriousness, growth) to determine the main priority of factors. In this case,
technique of collecting data is in the form of an approach to objects by observations,
interviews and literature studies using documents and data related to flash type fresh
water generator.
As a result of this mini thesis, author concludes that scale inside of feed
water side evaporator are caused by maintenance carried out is not in accordance
with maintenance plan, there is any trouble in the chemical dosing pump, content
of salt water is very high, and a lack of knowledge and experience of engineer about
flash type fresh water generator. The impact of that factors are scale inside
evaporator and it will decrease in water production. So, the efforts to resolve that
factors are doing descaling as per maintenance plan schedule, doing daily
inspection and maintenance of chemical dosing pump, doing injection of chemical
dosing as per manual book, give some training, examination and familiarization to
engineers about flash type fresh water generator on board.