ANALISA MENURUNNYA KUALITAS AIR PENGISIAN TERHADAP PENGOPERASIAN AUXILIARY BOILER DI MT. SINDANG
Collection Location
Repository PIP Semarang
Edition
Call Number
ISBN/ISSN
Author(s)
YUDHISTIRA, PRATIDINA PRATAMA
Subject(s)
Teknika
Classification
Series Title
GMD
Electronic Resource
Language
Publisher
Publishing Year
2024
Publishing Place
Collation
Abstract/Notes
ABSTRAKSI
Yudhistira Pratidina Pratama, 2019, NIT: 51145361 T, “Analisa Menurunnya
Kualitas Air Pengisian Terhadap Pengoperasian Auxiliary Boiler di MT.
SINDANG.”, skripsi Program Studi Teknika, Program Diploma IV,
Politeknik Ilmu Pelayaran Semarang, Pembimbing I: Sarifuddin, M.Pd,
M.Mar.E, Pembimbing II:Capt. Dwi Antoro, M.M, M.Mar
Ketel uap adalah bejana tertutup yang dapat menghasilkan uap panas dengan
tekanan lebih besar dari satu atmosfer, dengan jalan memanaskan air yang berada
di dalam ketel tersebut.Dalam kenyataannya, ketel uap sering kali mengalami
gangguan-gangguan, seperti yang pernah terjadi di MT. SINDANGpada tanggal
21 Oktober 2017, saat dilakukan pengujian air ketel, didapat hasil bahwa kadar
alkalinitas, pH yang terkandung di dalam air berada dibawah batas normal10.5-
11.5. Tujuan penelitian adalah mengetahui faktor-faktor serta upaya-upaya apa
yang dilakukan untuk mengatasi faktor-faktor penyebab menurunnya kualitas air
pengisian auxiliary boiler.
Metodedigunakan skripsi ini adalah metode penelitian deskriptif kualitaf.
Dalam hal ini penulis menggunakanmetode SWOT dan Hazop sebagai teknik
analisa datauntuk menganalisafaktor-faktor apa saja yang menyebabkan
menurunnya kualitas air ketel dan upaya apa yang dilakukan untuk mengatasi
faktor–faktor tersebut dengan mengidentifikasi kekuatan (strenghts), kelemahan
(weaknesses), peluang (opportunities), serta ancaman (threats) dari lingkungan
secara sistematisuntuk merumuskan strategi yang akan diambil.
Berdasarkan hasil penelitian yang telah dilakukan, dapat disimpulkan bahwa
penurunan kualitas air ketel disebabkan oleh dua faktor, yaitu a)Air destilasi yang
tercampur dengan air tawar. b)Kondisi air tawar dari darat tidak memenuhi syarat
untuk air ketel. Untuk mengatasi faktor-faktor tersebut dapat dilakukan dilakukan
pengujian air ketel di atas kapal, penambahan chemical dosing sertablowdown air
ketel.



ABSTRACT
Yudhistira Pratidina Pratama, 2019, NIT: 51145361.T, “Analysis of the
decreasing quality of filling water to auxiliary boiler operation atMT.
SINDANG”, Program Diploma IV,Technical, Merchant Marine
Polytechnic of Semarang, Supervising I: Sarifuddin, M.Pd, M.Mar.E and
Supervising II:Capt. Dwi Antoro, M.M, M.Mar
The auxiliary boiler is a closed tube that can produce steam at a pressure
greater than one atmosphere, by heating the water within the boiler. The
availability of hot steam is essential for the smooth operation of machinery in
need, for example for F.O fuel heater, freshwater heater, and others.Water used
in the process of steam formation is very influential on the condition of the boiler.
A decrease in water quality can affect the operation of the boiler, so water quality
should always be maintained.
Research method that writer use in preparation of this thesis is descriptive
qualitaf research method. In this case the writer use the SWOT method and Hazop
as a data analysis technique to analyze what factors cause the decrease of boiler
water quality and what efforts are done to overcome these factors by identifying
strengths, weaknesses, opportunities, and threats from the environment
systematically to formulate the strategy to be taken.
Based on the result of the research that has been done by the writer, it can
be concluded that water boiler degradation is caused by two factors, 1) distillate
water not yet widely available in ship caused by leakage of evaporator pipe on
FWG and mechanical seal damage at distillation pump. 2) Freshwater conditions
from land are not suitable for boiler water. To overcome these factors can be
done by checking to determine which pipe is leaking, patching the leaking pipes
using copper plugs, opening and closing the inlet valve and water outlet of the
evaporator heater slowly to avoid thermal shock which can cause pipeline
leakage, mechanical replacement seal on the distillation pump, and testing of
boiler water on board, addition of chemical dosing and water boiler blowdown.
Specific Detail Info