ABSTRAKSI


Achmad widianto, 51145303 T, 2019, “Pengaruh rusaknya filter pasir pada
Reverse Osmosis terhadap menurunnya produksi air tawar di MV. Alica”,
skripsi Program Studi Teknika, Program Diploma IV, Politeknik Ilmu
Pelayaran Semarang, Pembimbing I: Drs. Edy Warsopurnomo, M.M,
M.Mar.E, Pembimbing II: Dr. Capt. Mashudi Rofik M.Sc, M.Mar

Reverse Osmosis Plant adalah suatu permesinan bantu yang dioperasikan
untuk mengubah air laut menjadi air tawar dengan menggunakan prinsip tekanan.
Tujuan dari perawatan Reverse Osmosis adalah untuk. 1) Untuk mengetahui sebab
mengapa terjadi penurunan produksi air tawar, 2) Untuk mengetahui upaya apa
saja yang harus dilakukan untuk mengatasi penurunan produksi air tawar pada
Reverse Osmosis. Metode yang digunakan dalam skripsi ini adalah metode
Deskriptif Kualitatif dengan teknik SHEL dan USG sebagai metode untuk
menentukan penyebab dan upaya untuk menanggulanginya.
Penurunan produksi air tawar pada reverse osmosis disebabkan oleh
rusaknya outlet filter pasir yang disebabkan oleh tertahanya pipa outlet filter
karena banyaknya endapan yang ada di filter pasir menyebabkan tekanan di dalam
tanki yang menyebabkan rusaknya Outlet filter pasir.
Dari hasil penelitian ini disimpulkan Outlet Filter pasir (prioritas 1),
Komunikasi yang buruk (prioritas 2), Air laut kotor (pioritas 3), Kurang
berjalannya planned maintenance sistem (PMS) diatas kapal (prioritas 4). Saran
untuk menunjang kelancaran operasional kapal adalah Meningkatkan kesadaran
para crew akan pentingnya melaksanakan pembersihan dan perawatan komponen
Reverse Osmosis secara berkala. Dan Sebaiknya perusahaan segera melengkapi
dan mencarikan manual book yang sesuai dengan permesinan yang ada di kapal
agar seluruh crew tidak mengalami kesulitan dalam melaksankan perawatan
permesinan.



ABSTRACT


Achmad widianto, 51145303 T, 2019, "The Impact of filter damage on the
reverse osmosis system pertaining to the decrease of fresh water
production on MV. Alica", thesis of the Technical Study Program,
Diploma IV Program, suprervisor I: Drs. Edy Warsopurnomo, M.M,
M.Mar.E, supervisor II: Dr. Capt. Mashudi Rofik M.Sc, M.Mar

Reverse Osmosis Plant is an auxiliary machinery that is operated to
convert sea water into fresh water using the principle of pressure. The purpose of
the Reverse Osmosis treatment is to. 1) To find out the reason for the decline in
freshwater production, 2) To find out what efforts should be made to overcome
the decline in fresh water production at Reverse Osmosis.
The method used in this thesis is a Qualitative Descriptive method with
SHEL and USG techniques. As a method for determining causes and efforts to
overcome them. The decrease in freshwater production in reverse osmosis is
caused by damage to the sand filter outlet caused by the filter outlet pipe being
blocked because the amount of sediment in the sand filter causes pressure inside
the tank which causes damage to the sand filter outlet.
From the results of this study concluded sand filter outlet (priority 1), poor
communication (priority 2), dirty sea water (priority 3), lack of planned system
maintenance (PMS) on board (priority 4). Suggestions for supporting the smooth
operation of the ship are Increasing crew awareness of the importance of carrying
out periodic cleaning and maintenance of the Reverse Osmosis component. And it
is better for the company to immediately complete and find a manual book that is
in accordance with the machinery on board so that all the crew do not experience
difficulties in implementing machinery maintenance