Integrated Transport Resource Catalog

Pepustakaan Pusat Kementerian Perhubungan Republik Indonesia

Title
ANALISIS KEPADATAN SUBGRADE APRON HANGGAR-D BALAI KALIBRASI FASILITAS PENERBANGAN
Collection Location
Jurnal Ilmiah Aviasi PPI Curug
Edition
Call Number
ISBN/ISSN
1979-1534
Author(s)
Sukamto
Rahmawati, Kusumastuti
Subject(s)
Dynamic Cone Penetrometer (DCP)
California Bearing Ratio (CBR)
subgrade
density
Classification
Series Title
GMD
Electronic Resource
Language
eng
Publisher
Politeknik Penerbangan Indonesia Curug
Publishing Year
2016
Publishing Place
Collation
Abstract/Notes
Apron needs a subgrade with a certain density in order to meet the requirements of aircraft ACN. Subgrade from the ground requires special attention because it is potential to cause a decrease (consolidation) if it does not get adequate compaction process. Subgrade soil density needs to be tested first before undergoing subsequent construction process. Density test can be done by means of the Dynamic Cone Penetrometer ((DCP). Value of CBR is obtained by correlating the number of tool collisions with the depth of conus penetration. Subgrade soil density test is done in the apron construction area of hangar-D Curug Calibration Center for Flight Facilities
Specific Detail Info
https://journal.ppicurug.ac.id/index.php/jurnal-ilmiah-aviasi/article/view/24